Product description
Norpolifomor Comprehensive Air Quality Monitor
Norpolifomor air quality meter equips with advance industry technology and lastest chips to monitor the real time value of common pollutants in our daily life .Our Premium Air Quality Monitor enable us always detect for particle pollutants such as PM1.0/2.5/10, How about Formaldehyde ?Of course ,this air quality tester will do its job and we can make our countermeasures about how to tackle these pollutants which based on Treating Calculator.
Electrochemical Sensor Makes Testing Results More Accurate
The electrochemical sensor effectively eliminates other gas interference through multi-layer filtration, and accurately captures formaldehyde molecules. The electrochemical sensor uses the primary battery reaction principle of formaldehyde, and its output signal has a highly linear relationship with the formaldehyde concentration. With the cooperation of multi-layer filtration technology, formaldehyde molecules can be captured more accurately, and the anti-interference ability to non-formaldehyde molecules is stronger, and more accurate measurement can be achieved.
Advance Industry Technology and Lastest Chips
The new generation of PM2.5 laser is more accurate: laser scattering particle acceleration measurement method, using innovative light scattering and refraction algorithm, built-in gas and dust fast convection system, equipped with professional laser detection cavity, high-precision AD intelligent signal processing, greatly improving PM2.5 detection Accuracy. The data obtained by the formaldehyde detector/PM2.5 detector can be more scientifically designed the solutions for eliminating formaldehyde and haze
Calibration,System Setting and Pollutant Treating Calculator
Easy to calibrate the air quality tester,the operating steps as following:1,take the detector to air fresh environment,such as balcony,outdoor etc.2,run for more than 10min.3,press “start “,waiting 5mins for calibration count down(do not cover the detection ports).4,press “finish” after calibrated.
Setting for our air quality pollution monitor indoor ,you can enter setting interface by pressing “D”from main interface ,you would not fail to set the screen OFF/Shutdown time from the first two options,also you can adjust the work speed,brightness and factory set .So next we will introduce the sensor setting ,you would enable to adjust the data of HCHO/TEMP/PM2.5 once the measuring data was not accurate enough ,press the up/down or right/left arrow to select which parameter would need to be adjusted,press “save”when all parameters are set ,then you can gain the accurate data from our air pollution sensors.
Press”B”in the child interface ,then you can adjust the date and time .
Press”C”in the child interface ,it’s the multiply function ,you will enter the Intelligent formaldehyde and haze removal calculator.Press”A”and enter the mode of treating HCHO(Formaldehyde),you can select the acreage of our living room/master room/baby room/guest room/study room/kitchen ,the data of HCHO and the methods ,when all factors are ready ,then we can press”A”to calculate the time and cost for treating the pollutants .The step for treating Haze is the same with treating HCHO after entering the icon of Treating Haze .It must be a handy and practical tool to treat the polluted environment .Alarm setting would allow you to set the alarm based on the real-time data of HCHO ,you can set the alarm duration and alarming tune too.
How to test formaldehyde/TVOC:
1. Turn on the power switch
2. Preheating: Wait 3 minutes for preheating to complete.
3. Calibration:
a) After preheating, click the "Calibration" button on the comprehensive measurement interface to enter the intelligent calibration interface;
b) Place the instrument in a place with fresh air (such as balcony, outdoors);
c) Turn on the computer for more than 10 minutes;
d) Click the "Start" button, please wait for the 300-second calibration countdown;
e) After the countdown is over, click the "Finish" button to return to the comprehensive measurement interface, and you can directly take it into the indoor test.
4. Start the test: Close the doors and windows during the test. The test location can be the bedroom, living room, cupboard, cloakroom, etc. Take it to the test point and wait for more than 5 minutes ,then we can read the result directly. Then take it to the second place to test if you wanna switch testing location . Leave it for more than 5 minutes and get direct readings (it is recommended to gradually move from low concentration to high concentration during testing).
5. At the end of the test: turn off the tester, keep it properly.
Norpolifomor Air Quality Detector Widely Applies at Different Senarios